Duerkopp Adler HP Series Additional guide Manuál s instrukcemi Strana 78

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 84
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 77
EFKA AB220A5111
78
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
323 FLn 0 =Sewing foot is not lifted after power On 1 0 0 A
1 =Sewing foot is lifted after power On
This function is enabled only if TEACH IN is On
324 ti 0 =TEACH IN Off 1 0 0 A
1 =TEACH IN On
TEACH IN programming is possible only with V820.
Execution of pattern is possible without V820.
325 cti Erasing all TEACH IN data A
- Input code number 3112 after power On
- Press the E key
- Input parameter 325
- Press the E key
- Input 3112
- Press the P key
- The display briefly shows “deleted“, and a short
audible signal is issued
- Press the P key - all TEACH IN programs have
been erased!
401 EEP Immediate storage of all changed data 1 0 0 A
- Input code number 3112 after power On
- Press the E key
- Input parameter 401
- Press the E key
- Set display from 0 to 1
- Press the E or P key
- All data are stored
500 Sir Recall of Fast Installation Routine (SIR)
(see description on page 8!)
See next page for explanation of letter symbols!
1 12
03
3
3
1
1
1
11
2
2
1
1 02
311
Parameter
301
A2
A1
0 1
2
1
1 1 1
1 0
0
0 11
1 0
303
313312
302
10
10
0100100
0
0
0
0 100
0
0
0
0
100
0
0 100
0
0
10
10
10
0
318
[St]
308
10
0
0
0
0
[ms] [ms]
0
0
100 100
0 100
0
100
0 0
314 315
304 305
[St]
0
0
0
0
0
319
309
NA
100
100
10 100
10
10 10
10100
100100
100
100
10
NE
LS
0256/BILD4
100
FA-EP=0
Zobrazit stránku 77