EFKA AB220A511177
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
307 A1 Signal A1 On/Off 1 0 0 A
308 dA1 Stitches delaying signal A1 stitches 999 0 0 A
309 cA1 Stitch counting during signal A1 stitches 999 0 0 A
310 AA2 Selectable power transistors for signal A2 12 0 0 A
0 =No function
1 =Signal on output M1
2 =Signal on output M2
3 =Signal on output M3
4 =Signal on output M4
5 =Signal on output M5
6 =Signal on output M6
7 =Signal on output M7
8 =Signal on output M8
9 =Signal on output M9
10 =Signal on output M10
11 =Signal on output M11
12 =Signal on output VR
311 So2 Issue signal A2 3 0 0 A
0 =Signal until seam end (according to setting of
parameter 320)
1 =Signal over time
2 =Signal until seam end and drive stops
3 =Signal during stitch counting (according to setting
of parameter 319)
312 tr2 Starting point for signal A2 3 0 0 A
0 =Start at the beginning of the seam
1 =Start of the signal triggered by light barrier sensing
2 =Start of the signal when the drive stops at the seam
end
3 =Start from light barrier covered onwards at the
beginning of the seam
313 do2 Delay of signal A2 2 0 1 A
0 =No delay until signal On
1 =Delay over time until signal On
2 =Delay over stitches until signal On
314 dt2 Delay time until signal A2 On ms 2550 **) 0 0 A
315 St2 ON period of signal A2 ms 2550 **) 0 0 A
316 nA2 Speed mode when signal A2 is On 2 0 0 A
0 =Pedal controlled speed
1 =Limited speed n9
2 =Limited speed n11
317 A2 Signal A2 On/Off 1 0 0 A
318 dA2 Stitches delaying signal A2 stitches 999 0 0 A
319 cA2 Stitch counting during signal A2 stitches 999 0 0 A
320 bP0 Switch-off time of signals A1 and A2 1 0 0 A
0 =Signals effective until seam end
1 =Signals effective until pedal is in pos. 0 (neutral)
321 Std Suppression of the seam when 0 stitches are set 1 0 0 A
0 =Suppression Off
1 =Suppression On
322 dkn 0 =Correction seam Off 2 0 0 A
1 =Correction seam On
2 =Interruption of seam or pattern by thread trimmer
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.