EFKA AB220A5111
Technician Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
Parameter Designation Unit max min Preset Ind.
132 LSS 0 = Machine start possible with light barrier 1 0 0 *) A
uncovered or covered.
1 = Machine start blocked with light barrier
uncovered if parameter 131 = 1.
Machine start blocked with light barrier
covered if parameter 131 = 0.
133 LSE Thread trimming operation, when completing the seam 1 0 1 *) A
after light barrier sensing On/Off
134 SSt Softstart On/Off 1 0 0 *) A
135 SrS Ornamental backtack On/Off 1 0 0 A
136 FAr Trimming stitch backward On/Off 1 0 0 A
137 hP High lift for walking foot On/Off 1 0 A
139 nIS Display of machine speed On/Off 1 0 0 *) A
141 SGn Speed status for the seam with stitch counting 4 0 0 A
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 118) without influence by
the pedal (machine stop by pressing the pedal
to the basic position)
2 = Limited speed controllable by the pedal up to the
set limit (parameter 118)
3 = At fixed speed (parameter 118) can be interrupted
by full heelback
4 = At fixed speed (parameter 110) can be interrupted
by full heelback.
142 SFn Speed status for the free seam and for the seam with 3 0 0 A
light barrier
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 118) without influence by
the pedal (machine stop by pressing the pedal
to the basic position)
2 = Limited speed controllable by the pedal up to the
set limit (parameter 118)
3 = At fixed speed (parameter 118) can be interrupted
by full heelback (only for seams with light barrier).
143 kSA Stitch counting at the start of the seam (e. g. chain 3 0 1 A
suction
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 112) without influence by
the pedal (machine stop by pressing the pedal
to the basic position)
2 = Limited speed controllable by the pedal up to the
set limit (parameter 112)
3 = At fixed speed (parameter 112), can be suspended
or interrupted depending on the setting of
parameter 019.
144 kSE Stitch counting at the seam end (e. g. chain suction) 3 0 0 A
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 113) without influence by
the pedal (machine stop by pressing the pedal
to the basic position)
2 = Limited speed controllable by the pedal up to the
set limit (parameter 113)
3 = At fixed speed (parameter 113), can be suspended
or interrupted depending on the setting of
parameter 019.
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.